Replacing a failed transformer

Send the nameplate and the date the site needs power back. The replacement is matched to the existing installation first, and every supply option is stated with its condition and delivery basis.

Start with

Nameplate photograph
the whole plate, legiblerating, voltages, vector group, impedance
Photographs of the unit
front, sides and cable connectionsthey show the fittings and the connections
Date power is needed
the latest acceptable dateit decides which options are worth checking
Stock
none is heldavailability is checked per request
Outline drawing for orientation.Not a photograph of a specific unit. Arrangement, enclosure and dimensions depend on the unit offered.

Daverlan holds no stock and runs no emergency crew. What it can do quickly is turn a nameplate into a specification a manufacturer can quote, check which supply routes fit the date, and say plainly when none of them does.

What the replacement has to match

ItemWhy it mattersWhere it comes from
Rating and voltage pairA different ratio will not work on the existing network and installationThe nameplate
Vector groupIt must suit the earthing arrangement and any unit in parallelThe nameplate
ImpedanceUnits in parallel share load in proportion to it, and it sets the fault level at the boardThe nameplate or the test report
Tapping rangeThe network voltage at the connection point has to be reachableThe nameplate
Footprint, cable boxes and bushing positionsA unit that does not fit the plinth or the cables adds site workPhotographs and the site drawing
Construction and liquidThe room, the containment and the fire strategy were built for itThe nameplate and the site

What happens after the nameplate arrives

  1. Read and check

    The plate is read into a specification, and anything illegible or missing is asked for in the first reply.

  2. Match the installation

    The items in the table above are confirmed, so an offer is only made for a unit that fits.

  3. Check the routes

    Manufacturers whose published range covers the specification are asked, including whether a unit to that specification can be built or supplied by the date given.

  4. Set out the options

    Each option is stated with its condition, its documents, its delivery basis and its validity, side by side.

Supply options, and what each one needs

OptionWhen it is consideredWhat has to be on file
New, built to the specificationAlwaysDatasheet, drawing, routine test report on delivery
New, from a manufacturer's short delivery rangeWhere a manufacturer publishes such units and one matchesThe same documents, and the match confirmed item by item
Surplus, unusedOnly when you accept itDocuments, storage history and a test before dispatch
RefurbishedOnly when you accept itThe work done, the parts replaced and the test results

No option is assumed to exist. Whether any unit is available by the date given is established per request and stated in writing.

What we need to quote a replacement

01Nameplate photograph, and photographs of the unit and its connections
02The latest date the site can accept, and whether a temporary supply exists
03Indoor or outdoor, ambient temperature, altitude and any corrosive or dusty exposure
04The standard and the loss requirement the destination market applies
05Quantity, destination and the date the equipment has to be on site
06Whether surplus or refurbished units are acceptable, or new only

Common questions

How long does it take to replace a transformer?

It depends on whether a matching unit exists, on the manufacturer's loading if one has to be built, and on the site work. No general figure is published here. Each option in a quotation carries its own delivery basis.

Can you send a unit today?

No. No stock is held. What can be done quickly is the specification and the check of which routes fit the date.

Do you install or commission the replacement?

No. Removal, installation, testing and commissioning belong to a qualified contractor, and the connection to the network operator where it applies.

Related

Send us the requirement

Send the rating, the voltage and the destination, or submit the specification, drawing or nameplate. Anything missing is raised before it reaches a supplier.