Protection and control

Protection relays

Numerical relays that measure currents and voltages from instrument transformers and trip the breaker when the scheme's conditions are met.

At a glance

Standard
IEC 60255 seriesmeasuring relays and protection equipment
Inputs
current and voltage transformersratios and classes set by the scheme
Functions
overcurrent, earth fault, differential and moreset by the protected equipment
Communication
protocol set by the substation system
Settings
applied at commissioningagreed with the network operator where required
Outline drawing for orientation.Not a photograph of a specific unit. Arrangement, enclosure and dimensions depend on the unit offered.

A protection relay is specified by the equipment it protects and the scheme it sits in. A feeder relay commonly provides overcurrent and earth fault protection. A transformer relay adds differential protection. A motor relay adds thermal and starting supervision. The functions are often referred to by their ANSI device numbers, for example 50 and 51 for overcurrent and 87 for differential protection.

The relay depends on what feeds it. The current and voltage transformer ratios and classes, the auxiliary supply voltage and the communication protocol of the substation system all have to match, and settings are calculated from the network study and applied at commissioning.

What gets specified

ParameterTypical optionsWhat decides it
Protected equipmentFeeder, transformer, motor, generator, busbarThe single line diagram
Protection functionsOvercurrent, earth fault, differential, voltage, frequencyThe protection scheme
Current and voltage inputs1 A or 5 A secondary, voltage inputsThe instrument transformers
Auxiliary supplyDC or AC voltageThe station battery or auxiliary system
CommunicationSubstation protocol and portsThe control system
MountingFlush panel mounting, cut out sizeThe panel, especially for replacements
Inputs and outputsNumber of binary inputs and output contactsInterlocking and alarm needs

Typical options are the ones buyers most often specify. They are not a list of what is available, which is confirmed per enquiry.

Applicable standards

StandardWhat it covers
IEC 60255-1Measuring relays and protection equipment, common requirements
IEC 60255 seriesFunctional and product requirements for protection relays

The standard that applies is set by the specification and the destination market. Editions change, so the edition cited in a specification is confirmed in the quotation.

Documents normally requested

DocumentWhat it evidences
Technical datasheetRatings, functions and the variant offered
Type test report or certificateThe design has passed the tests of its standard
Dimensional drawingMounting, cut out and connection positions
Wiring or connection diagramTerminals, auxiliary supply and communication
Settings and configuration filesWhere a device is supplied preconfigured
ManualInstallation, commissioning and operation

Where a device replaces an existing one, the nameplate, model and firmware of the existing device are the most useful documents to send.

What we need to quote accurately

01Device type and the system voltage it serves
02Rated current and the short circuit breaking or withstand values required
03The protection scheme and functions needed, and the scheme it must integrate with
04Auxiliary supply voltage and communication protocol
05Whether this replaces an existing device, with its nameplate or model if known
06Quantity, destination, required delivery date and acceptable condition
07Current and voltage transformer ratios, and the secondary current rating
08The communication protocol of the substation system

Delivery and logistics

Devices are lighter to move than transformers and switchboards, but compatibility is the harder part of the delivery. A replacement breaker has to fit the existing panel, a relay has to fit the cut out and the scheme, and a firmware or communication mismatch can make a correct device unusable on the day.

Delivery dates are stated in each quotation for the specific item offered. We do not publish a general lead time.

Common questions

Do you calculate protection settings?

No. Settings come from the network study and are applied by the party that commissions the scheme. We source relays specified to carry the functions and interfaces the scheme needs.

Related

Request a quote for this equipment

Send the rating, the voltage and the destination, or submit the specification, drawing or nameplate. Anything missing is raised before it reaches a supplier.